Wall Assembly 2

Outer Wall Assembly
A lot has been happening! Since the last post we have...

Completed the Breezeway and Garage Foundation

Completed the Septic System 

Completed the Outer Wall Assembly (We'll refer to it as the Cladding Wall from now on)
(View of the Front and South Side)

(View of the Back)

(View of the North Side)

Needless to say we have turned a few heads. The most common question is where the windows are going or why are they covered up?


        Simply put, we are not just going to say we are building a super tight house, we are going to test it before any insulation, drywall, windows, plumbing, or electric is installed to ensure its tightness. And then after those other components are installed we can test again to check those individual components for air tightness. When we are ready to perform the initial blower door I will go into this into a little more detail. 

Lets take a look at the Cladding Wall Assembly and Details:
         

The Cladding Wall sits on the mud sill and extends upwards to the underside of the truss (just under 20 feet in total length). We did change the bottom plate from a 2x4 in the detail to a 2x6 to improve bearing on the concrete.  We did this "step" to allow for continuous insulation around the rim board.


           In a perfect world we wanted to wait to install the cladding wall until after the 1st blower door test but to keep the framing crew busy we decided to frame and install the cladding wall. We built the wall in "window sections" meaning we framed the full 2 story section on the ground to include only any 1st and 2nd floor windows and doors. However we are glad we installed the cladding wall before the trusses. The gable end truss will now have the cladding wall to sit on, and we don't have to "cantilever" the last 2 trusses off of the last common truss. It was also much easier to work from the top of the 2nd floor without trusses in the way.

We were able to lift the wall from the 2nd floor with a pulley and drop it in place. Once all of the window sections were placed we filled in the rest with 20 foot long 2x4's one at a time.

We did install blockers about 1/2 way up the cladding wall to provide stability and maintain spacing. 20 foot long 2x4's are not always the straightest.

The total thickness of the wall is 15.5" from outside face of cladding wall to inside face of structural wall. 


The space between the inner wall and the cladding wall is 7.5"

Here is a screen shot of the Passive House Planning Package (PHPP) calculation of our wall assembly:
This overall wall assembly, framing included, has an R-value of R-52. 

AND...
Trusses have been delivered
(House Trusses dropped next to a 40' storage container for perspective)
Another post will come shortly!

Comments

Popular posts from this blog

Window Installation

With all of the engineering and design that goes into a house like this, why would window installation be any different? EVERYTHING in a passive house is modeled, examined, and optimized thermodynamically. For now we will be talking about the thermodynamic analysis of the Passive House Windows and how this translates to the positioning of the windows within the wall system. A typical new construction window comes with a nailing flange that is part of the frame of the window. This requires the window to be nailed directly to the wall, resulting in the window being flush with the outer edge of the exterior wall. Passive House windows don't come with the nailing flange, this allows flexibility in location of installation within the wall system. The fact is, in a thick wall (12 inches or more, further details on wall thickness will be addressed in a later post) you typically don't want to install the window on the outside of your wall. You want to install the window in the middle o...

Wall Assembly 1

Double Wall Construction Maybe I am biased to double wall construction because the company I work for Airtight Services  is a cellulose insulation company; but it is still probably the most cost effective way to achieve the R-values necessary for Passive House. Based on our energy model we needed to achieve about an R-54 wall. There were a couple options: 2x6 wall with 6" of polyisocyanurate rigid foam to the outside There are some more difficult window installation details when your window is cantilevered over nothing but foam. Some long screws are need to attached a furring strip over the rigid foam (9" long) and those can add considerable cost to the project - upwards of $0.75 each The labels on rigid foam insulation scared me a little bit too -  15 YEAR LIMITED THERMAL WARRANTY Polyisocyanurate has the WORST embodied energy of the good types of insulation meaning it takes the most amount of energy to make relative to how much it will save This graph was posted on Green Bu...