Thermal Bridges

Thermal Bridges

Forgive me for this post, I have been thinking about how I wanted to say this without sounding too technical. I'm going to try to simplify this a little bit. 

A thermal bridge is any location in a building where conduction of heat can travel from inside to outside easily. 
An Infrared scan will help visualize these bridges. This is NOT an X-Ray. The infrared camera only measures surface temperatures. This is a thermal image of a poorly installed window. So what you are seeing are the yellow/white colors are warm temperatures and the blue and black colors are cold temperatures. As you can see, there is a substantial thermal bridge around the window opening allowing the cold temperatures outside to come in. In this case the efficiency of the window doesn't matter due to the poor quality installation. There is a temperature difference of over 12 degrees inside the box. This spot will feel cold all the time!


Proper thermal bridge free installation of the window will show minimal changes in temperature, (See my Window Installation Post).

Thermal Bridge Free Construction is vital for a passive house. Eliminating cold spots also will improve comfort, eliminate the potential for condensation and boost the efficiency of the house.

Modeling

Thermal Bridge analysis is done with a computer program called THERM. Once a wall assembly is designed, we can model all of the intersections of the house (Floor to Wall, Wall to Window, Wall to Attic, Basement Slab to Foundation Wall, Etc). Passive House studies have shown that maintaining surface temperatures within 6 degrees of each other is optimal for comfort (due to radiant temperature gains and losses) THERM allows us to simulate all of the assembly interior surface temperatures to ensure all of the surfaces of the house are within 6 degrees of each other. That is right... Your Basement Floor is within 6 degrees of the upstairs ceiling. The window frames are within 6 degrees of your living room floor. This is the recipe for comfort!

                                                                                                                                                                          
When you combine an air tight structure with the THERM analysis you can ensure superior comfort, superior efficiency, zero mold growth potential and longevity of structure. 

Now I do need to clarify that Thermal Bridges are much more complicated than I described above. I would need to go into ψ values, boundary conditions, ISO Testing (International Organization for Standardization), positive and negative thermal bridges, and more. In fact there is a 3 day course you can take after you get certified as a Passive House Consultant just to learn how to identify and properly analyze. 





Comments

Popular posts from this blog

Window Installation

With all of the engineering and design that goes into a house like this, why would window installation be any different? EVERYTHING in a passive house is modeled, examined, and optimized thermodynamically. For now we will be talking about the thermodynamic analysis of the Passive House Windows and how this translates to the positioning of the windows within the wall system. A typical new construction window comes with a nailing flange that is part of the frame of the window. This requires the window to be nailed directly to the wall, resulting in the window being flush with the outer edge of the exterior wall. Passive House windows don't come with the nailing flange, this allows flexibility in location of installation within the wall system. The fact is, in a thick wall (12 inches or more, further details on wall thickness will be addressed in a later post) you typically don't want to install the window on the outside of your wall. You want to install the window in the middle o...

Wall Assembly 1

Double Wall Construction Maybe I am biased to double wall construction because the company I work for Airtight Services  is a cellulose insulation company; but it is still probably the most cost effective way to achieve the R-values necessary for Passive House. Based on our energy model we needed to achieve about an R-54 wall. There were a couple options: 2x6 wall with 6" of polyisocyanurate rigid foam to the outside There are some more difficult window installation details when your window is cantilevered over nothing but foam. Some long screws are need to attached a furring strip over the rigid foam (9" long) and those can add considerable cost to the project - upwards of $0.75 each The labels on rigid foam insulation scared me a little bit too -  15 YEAR LIMITED THERMAL WARRANTY Polyisocyanurate has the WORST embodied energy of the good types of insulation meaning it takes the most amount of energy to make relative to how much it will save This graph was posted on Green Bu...